Installation of a stationary hydraulic hammer at a height

[1] Turkstra C.J. Theory of Structural Design Decisions, SM Studies Series No. 2. Ontario, Canada: Solid Mechanics Division, University of Waterloo. 1970.

[2] Eurocode - Basis of structural design : EN 1990:2002+A1. - Brussels : Management Centre, 2002. - 116 с. - (European Standard).

[3] Eurocode 2: Design of concrete structures - Part 1-1: EN 1992-1-1:2004.- Brussels: Management Centre, 2008. - 225 с. - (European Standard).

[4] EN 1991-1-3. Eurocode 1 – Actions on structures. Part 3: Actions induced by cranes and machinery – Brussels: CEN, 2003. – 43 P.

[5] Eurocode 3: Design of steel structures – Part 4-1: Silos : EN 1993-4-1. – Brussels : Management Centre, 2007. – 114 с. – (European Standard).

[6] Barashikov A.Y., Malyshev O.M. Estimation of technical condition of building structures, buildings and structures. - K.: NMC Derznaglyadodohoronpraci Ukrainy, 1998. - 23 p.

[7] DBN V.3.1-1-2002. Repair and strengthening of bearing and enclosing building constructions and bases of industrial buildings and constructions.. State Committee on Construction and Architecture of Ukraine. Kiev. 2003 - 82 pp. - (State building codes of Ukraine).

[8] Gulvanessian H. and Holicky M. Eurocodes: Using Reliability Analysis to Combine Action Effects. Proceedings of the Institution of Civil Engineers Structures & Buildings. August 2005, vol. 158, no. SB4, pp. 243—252.

[9] Skuturna, T., & Valivonis, J. (2016). Experimental study on the effect of anchorage systems on RC beams strengthened using FRP. Composites Part B: Engineering, 91, 283-290. https://doi.org/10.1016/j.compositesb.2016.02.001

[10] Demir, A., Ercan, E., & Demir, D. D. (2018). Strengthening of reinforced concrete beams using external steel members. Steel and Composite Structures, 27(4), 453-464. ) DOI: https://doi.org/10.12989/scs.2018.27.4.453

[11] Helal, Y., Garcia, R., Pilakoutas, K., Guadagnini, M., & Hajirasouliha, I. (2016). Strengthening of short splices in RC beams using post-tensioned metal straps. Materials and Structures, 49(1-2), 133-147. DOI 10.1617/s11527-014-0481-6

[12] Jin, F., & Lees, J. M. (2019). Experimental Behavior of CFRP Strap–Strengthened RC Beams Subjected to Sustained Loads. Journal of Composites for Construction, 23(3), 04019012. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000936

[13] Lee, H. Y., Jung, W. T., & Chung, W. (2017). Flexural strengthening of reinforced concrete beams with prestressed near surface mounted CFRP systems. Composite Structures, 163, 1-12. https://doi.org/10.1016/j.compstruct.2016.12.044

[14] Garcia, R., Pilakoutas, K., Hajirasouliha, I., Guadagnini, M., Kyriakides, N., & Ciupala, M. A. (2017). Seismic retrofitting of RC buildings using CFRP and post-tensioned metal straps: shake table tests. Bulletin of Earthquake Engineering, 15(8), 3321-3347. http://dx.doi.org/10.1007/s10518-015-9800-8

[15] Yang, S. H., Cao, S. Y., & Gu, R. N. (2015). New technique for strengthening reinforced concrete beams with composite bonding steel plates. Steel and Composite Structures, 19(3), 735-757. https://doi.org/10.12989/scs.2015.19.3.735

Slipych, О., Romanenko, K., Kravtsova, D., & Bondar, О. (2021). Installation of a stationary hydraulic hammer at a height. Journal of Kryvyi Rih National University, 19(1), 64-70. https://doi.org/10.31721/2306-5451-2021-1-52-64-70
en